Fire Panels

Include addressable and conventional configurations, suppression system activation, voice evacuation, emergency power shutdown, and more.

Fike FCP Fike Cheetah® Xi Fike SHP PRO®

FCP

CheetahXI

SHP

Function

Addressable control panel with comprehensive functionality

Addressable, modular fire alarm and suppression system

Conventional fire alarm and suppression panel

Benefit

Supports up to 159 sensors and modules per loop; ECS models include voice evacuation functions.

Integrates with clean agent water mist systems; Xi 50 supports up to 50 devices, and Xi 1016 up to 1016 devices.

Designed to serve the needs for smaller applications; supports 25 convention devices per circuit.

Approvals

UL | FM

UL | FM

UL | FM

Datasheet (FCP 75)

Datasheet

Datasheet

Air Sampling

Continuously measures a room's air quality for early signs of combustion, even before smoke is visible.

VESDA-E-VEP VESDA-E VES VESDA-E VEU VESDA-E VLI VESDA-E VEA

VESDA-VEP

VESDA-VES

VESDA VEU

VESDA - VLI

VESDA-VEA

Function

Mainstream aspirating smoke detector

Sector addressable aspirating smoke detector

Highest sensitivity aspirating smoke detector

Industrial aspirating smoke detector

Centralized aspirating smoke detector

Benefit

Combines advanced air sampling detection technology with flexibility for use in a wide range of applications.

Monitors smoke density by individual pipe, allowing a single zone to be divided into four sectors where pinpoint location is essential.

Offers an ultra-wide sensitivity range, long linear piperuns and more sampling holes, ideal for high airflow or high-ceiling environments.

Designed to protect industrial applications and harsh environments with a fail-safe intelligent filter and advanced clean-air barrier.

Includes the performance of smoke detectors with centralized testing and maintenance; ideal for hospitals, hotels and other highly populated buildings.

Approvals

UL | ULC | FM | VdS | CE | CSFM | NF-SSI | VNIPO | ActivFire | CCC | EN

UL | ULC | VdS | CE | CSFM | ActivFire | EN 54-20 | ISO 7240-20

UL | ULC | FM | VdS | CE | CSFM | NF-SSI VNIPO | ActivFire | CCC | EN 54-20 | ISO 240-20

UL | ULC | FM | CE | ActivFire,UKCA | LPCB | NF | SIL 2 | EN54-20

UL | ULC | FM | VdS | CE | CSFM | EN 54-20 | ISO 7240-20 | ActivFire

Datasheet

Datasheet

Datasheet

Datasheet

Datasheet

Flame Detectors

Quickly identifies hydrocarbon fuel and gas fires. Operates in all weather and light conditions; triple spectrum technology provides immunity to false alarms.

FIK-IR3 FIK-IR3-H2 FIK-UV-IR FIK-HD Fike Fire Watch

IR3-HD

UVIR Detectors

UV-IR

IR3-HD

Fire Watch

Function

Hydrocarbon flame detector

Hydrogen flame detector

Hydrocarbon and hydrogen flame detector

Optional HD camera

Deployable fire watch unit

Benefit

Detection within 40 milliseconds of fireballs or explosions; detects standard fires 50 ft away within 1.3 seconds, and fires 230 ft away within 3.7 seconds.

Detection within 40 milliseconds of fireballs or explosions; detects hydrogen fires 0-66 ft away within 1.2 seconds, and fires 67-100 ft away within 4 seconds.

Ultra fast detection within 5 milliseconds of fireballs or explosions; detects fires up to 100 ft away for a 1ft n-heptane fire.

Provides live video feed and recording one minute pre-event and three minutes post-event. Fike Video Analytics may also be integrated for oil mist and smoke detection.

Equipped with one or two Fike flame detectors, satisfies temporary or long-term fire watch needs after hot work or if a fire protection system is disabled.

Approvals

ATEX | IECEx | FM | FMC | CSFM | INMETRO

ATEX | IECEx | FM | FMC | CSFM | INMETRO

ATEX | IECEx | FM | FMC | CSFM | INMETRO

ATEX | IECEx | FM | FMC | CSFM

FM-review

Datasheet

Datasheet

Datasheet

Datasheet

Brochure

Linear Heat Detection

A continuous run of heat detectors within a versatile cable; designed for use in a variety of indoor and outdoor applications and harsh environments.

Digital Temperature Sensing (DTS) Protectowire

Digital Temp Sensing

Linear Heat

Function

Fiber optic distributed temperature sensing cable

General purpose linear heat cable

Benefit

Provides continuous temperature profile along the entire length of the sensor cable to identify the location of overheated areas before they become hazardous.

Activates alarm once fixed temperature is reached anywhere along the cable; suited for areas where access is difficult or hazardous.

Approvals

UL | FM | ULC | CE | VDS

UL | FM | CSFM

Datasheet

Video Detection

Uses live video technology to monitor hazards such as oil mist or overheated surfaces which are difficult to identify with other detection methods.

Fike Video Analytics Thermal Imaging Cameras

VID

Mobotix

Function

Flame, smoke and oil mist detection system

Temperature monitoring technology

Benefit

May be integrated on existing or new camera networks to provide advanced notification of an impending hazard prior to activating fire alarm, suppression and evacuation systems.

Visualizes obscured fires and monitors temperature of potential overheated malfunctioning equipment; generates report to log temperature data to identify where maintenance is required.

Approvals

UL | FM | CE

Datasheet

Datasheet

Gas Detection

Provides early warning of the presence of gases for occupant protection and system monitoring.

Sensepoint XCD Sensepoint XCL Large Bore Sensepoint XCL Micro Bore Li-ion Tamer Gas Detection

Sensepoint XCD

Sensepoint XCL

XCL Micro Bore

Li-ion tamer

Industrial gas detector

Aspirating gas detector

Aspirating gas detector

Energy storage system gas detector

Monitors flammable and toxic gas hazards in industrial and commercial environments; comes pre-configured and offers simple installation on surfaces and horizontal or vertical pipes.

Used in tandem with an Xtralis aspirating smoke detection pipe network to identify early warning signs of both harmful or explosive gasses and fire hazards.

Used in tandem with an VESDA-E VEA aspirating smoke detection pipe network to identify early warning signs of both harmful or explosive gasses and fire hazards.

Monitors battery energy storage systems for off-gas of a malfunctioning lithium ion battery; connects with BMS or fire panel to shut down power.

EN/UL/IEC 61010-1 | CE | UL2075

CE | ETL | EN/UL/IEC 61010-1 | CE | UL2075

CE | EN | UL | EN/UL/IEC 61010-1 | CE | UL2075

CE | ETL | ETL listed to UL 61010 | EN 61326 | RoHs 3 EU 2015/863

Datasheet

Datasheet

Datasheet

Datasheet

Bi-Directional Amplifiers (BDAs)

Also known as Emergency Responder Communication Enhancement Systems (ERCES), BDAs are required by both international building and fire codes, as they upgrade the in-building radio signal to provide reliable, two-way communications for safety personnel.

Learn More

BDA

Chemical Agent Fire Suppression

Waterless, electrically non-conductive suppressing agents which remove heat and dissolve fires at the molecular level.

3M™ Novec™ 1230 FK-5-1-12 FM-200™ ECARO-25® Small Space

3M Novec

FK-5-1-12 Bl Product Slider

FM-200

Ecaro

Small Space

Function

Fluoroketone agent

Fluoroketone agent

Hydrofluorocarbon agent

Hydrofluorocarbon agent

Heat-reactive tubing

Benefit

Has a global warming potential of less than one, 99.9 percent less than hydrofluorocarbons.

Viable alternative to 3M Novec 1230; may have quicker lead times.

Most used and globally recognized chemical agent.

Cost-effective chemical agent; requires 20 percent less agent per cubic/meter than FM-200.

Flexible tubing routed through electrical cabinets or CNC machines to provide agent immediately within these confined spaces.

Approvals

CE | EN | UL | ULC | FM

FM | UL | ULC

FM | UL | ULC | CE

FM | UL | ULC

UL

Datasheet

Datasheet

Datasheet

Datasheet

Datasheet

Water-Based Suppression

Ideal for many applications where traditional sprinkler systems would result in destroyed electronics, collateral damage and excessive cleanup, and uses up to 90 percent less water than conventional fire sprinkler systems.

DuraQuench® Micromist® Fire Water Monitors

Duraquench

Micromist

Fike Fire Monitors

Function

Engineered skid-mounted pump system

Pre-engineered, self-contained water mist system

Flame, smoke and oil mist detection system

Benefit

Connects directly to a building’s water supply, tank or reservoir to provide an unlimited discharge of water mist; may protect volumes with 75 percent less water than a conventional sprinkler system.

Pre-assembled with all necessary components to offer a simple-to-install water mist solution; particularly suited for applications where a water source is unavailable.

Discharges up to 1,320 gallons per minute up to 87 yards away in a total nozzle spray pattern; frequently combined with Fike flame detectors to create the ultimate early warning water- or foam-based fire suppression solution.

Approvals

FM | NFPA 750

FM | NFPA 750 (intermediate pressure system)

Datasheet

Datasheet

Learn More

Inert Gas Suppression

Inert gas is used to reduce oxygen levels to a concentration unsustainable for fires but safe for people and the environment. Its superior design qualities allow for long pipe runs and small-diameter piping with low pressure ratings and couplings from the inert gas containers all the way to the nozzles.

Learn More

Inert Gas

Carbon Dioxide (CO2) Suppression

Reduces oxygen to a point where combustion cannot occur or be sustained. Extremely effective and versatile for Class A, B or C hazards, and is often used to protect localized applications.

Learn More

CO2

Ready To Learn More?